Limit of Iron

Limit of Iron

Summary Purpose: Verify iron content does not exceed the specified limit. Principle: The monograph describes reduction and complexation steps that produce a colored species which is compared to a blank or limit standard; absence of color beyond the blank indicates compliance.

Step-by-Step Instructions

  1. Add citric acid and thioglycolic acid to the sample solution.

  2. Make the solution alkaline with stronger ammonia water.

  3. Wait 5 minutes and compare the pink color to a standard iron solution.

Acceptance Criteria